Central loose tube cable, outdoor-use, CSTA - steel tape armour, HDPE sheath - black, 01x04-fibers G657.A1

R855728

Corrugated steel tape armoured central loose tube cable with excellent mechanical protection and thus secure rodent protected.

With up to 24 fibers maximum, suitable for outdoor duct or direct buried installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Central loose tube cable

Jacket material

UV stable HDPE

CPR classification Fca
Armour

Corrugated steel tape armoured (CSTA)

Fiber type

G.657.A1

Fiber Count 4
Application

outdoor-use

Cable family code OX1ECH
DIN/VDE Code A-DQ(ZN)(SR)2Y wbg
DoP no.: D9911
Loose-tube count 1
Fiber count per tube 24
Loose tube nominal diameter [mm] 3 mm
Outer jacket nominal thickness [mm] 1.2 mm
Cable outer diameter [mm] 7.7 mm
Cable version

n.a

Standard put-up length on drum 2100 m ± 5%
Maximum length on drum 4100 m ± 5%
RoHS

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 70.0 kg/km / 47 lbs/1000ft
Tensile performance - in service

500 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

1500 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

2500 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

20 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling - reversible -30 °C +70 °C / -22 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Transport / store temperature -30 °C to +70 °C / -22 °F to +158 °F