FTTH mini loose tube cable, Micro, universal-use, no armour, FRLSZH sheath - black, Fca, 01x04-fibers G657.A1

R851139

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

FTTH - Mini loose tube cable

Jacket material

UV stable FRLSZH

CPR classification Fca
Fiber type

G.657.A1

Fiber Count 4
Application

universal-use

Cable family code MT1RF
DIN/VDE Code U-DQ(ZN)H (2FRP 0,5)
DoP no.: D9038
Loose-tube count 1
Loose tube nominal diameter [mm] 1.2 mm
Outer jacket nominal thickness [mm] 0.9 mm
Cable outer diameter [mm] 3 mm
Cable version

Micro cable

Standard put-up length on drum 2100 m ± 5%
Halogen free, acid gases

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 11.0 kg/km / 7 lbs/1000ft
Tensile performance - during installation

150 N

Tensile Performance during Installation TestMethod

EN 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Impact resistance

1 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,1 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

EN 60794-1-21:E7

Torsion acceptance criteria

no damage

Kink

d = 40 x cable diameter

Kink test method

EN 60794-1-21:E10

Kink acceptance criteria

no damage

Cable bend

d=40 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R = 40 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -20 °C -70 °C / -4 °F -94 °F
Temperature cycling - reversible -30 °C +70 °C / -22 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Transport / store temperature -30 °C to +70 °C / -22 °F to +158 °F