Stranded loose tube cable, fire-resistant, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, Fca, 12x12-fibers G657.A1

R857651

Fire-resistant and corrugated steel tape armoured stranded loose tube cable with excellent mechanical protection and thus secure rodent protected.

The cable features a two jacket construction (both sheath in FRLSZH), is built with up to 144 fibers in a 12-strand stranding and is suitable for indoor or outdoor duct installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Stranded loose tube cable

Jacket material

UV stable FRLSZH

CPR classification Fca
Armour

Corrugated steel tape armoured (CSTA)

Cable design

Double jacket

Fiber type

G.657.A1

Fiber Count 144
Application

universal-use

Cable family code QT3x2.3EFCF
DIN/VDE Code U-DQ(ZN)H(SR)H wbg nx2,3 fr
DoP no.: D9064
Loose-tube count 12
Fiber count per tube 12
Loose tube nominal diameter [mm] 2.3 mm
Loose-tube colour coding

1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black)

FRP/coat. CSM nominal thickness [mm] 2.8 / 7.8
Outer jacket nominal thickness [mm] 1.5 mm
Cable outer diameter [mm] 21.5 mm
Cable version

Fire-resistant

Standard put-up length on drum 2100 m ± 5%
Halogen free, acid gases

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 500.0 kg/km / 335 lbs/1000ft
Tensile performance - in service

1100 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

3500 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

2500 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

20 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -40 °C +70 °C / -40 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -40 °C to +70 °C / -40 °F to +158 °F
Transport / store temperature -40 °C to +70 °C / -40 °F to +158 °F
Creating documents