Corrugated steel tape armoured central loose tube cable with excellent mechanical protection and thus secure rodent protected.
With up to 24 fibers maximum, suitable for indoor or outdoor duct or direct buried installation.
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | Central loose tube cable |
Jacket material | UV stable FRLSZH |
CPR classification | Dca |
Armour | Corrugated steel tape armoured (CSTA) |
Fiber type | G.657.A1 |
Fiber Count | 24 |
Application | universal-use |
Cable family code | UX1ECF |
DIN/VDE Code | U-DQ(ZN)(SR)H wbg |
DoP no.: | D9026 |
Loose-tube count | 1 |
Fiber count per tube | 24 |
Loose tube nominal diameter [mm] | 3 mm |
Outer jacket nominal thickness [mm] | 1.2 mm |
Cable outer diameter [mm] | 7.7 mm |
Cable version | n.a. |
Standard put-up length on drum | 2100 m ± 5% |
Maximum length on drum | 4100 m ± 5% |
Halogen free, acid gases | Pass |
CPR classification detail | Dca-s2,d2,a1 |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 84.0 kg/km / 56 lbs/1000ft |
Tensile performance - in service | 500 N |
Tensile performance - in service test method | IEC 60794-1-21:E1 |
Tensile performance - in service acceptance criteria | Δα ≤ 0,05 dB |
Tensile performance - during installation | 1500 N |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Crush resistance - long term | 2500 N/100mm |
Crush resistance - long term test method | IEC 60794-1-21:E3A |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Impact resistance | 20 Nm, 3 impacts, d=20 mm, R=300 mm |
Impact resistance test method | IEC 60794-1-21:E4 |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
Torsion test method | IEC 60794-1-21:E7 |
Torsion acceptance criteria | no damage |
Cable bend | d=20 x cable diameter, 4 turns, 3 cycles |
Cable bend - test method | IEC 60794-1-21:E11A |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Repeated bending | R=20 x cable diameter, 25 cycles |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending acceptance criteria | no damage |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Temperature cycling | -30 °C +70 °C / -22 °F +158 °F |
Temperature cycling - reversible | -35 °C +70 °C / -31 °F +158 °F |
Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
Operation temperature | -30 °C to +70 °C / -22 °F to +158 °F |
Transport / store temperature | -35 °C to +70 °C / -31 °F to +158 °F |