DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | Central loose tube cable |
Jacket material | FRLSZH |
CPR classification | B2ca |
Armour | Rodent protection |
Fiber type | OM3 |
Fiber Count | 8 |
Application | indoor-use |
Cable family code | IFEF FiRis |
DIN/VDE Code | J-B(ZN)H wbg |
DoP no.: | D9082 |
Loose-tube count | 1 |
Fiber count per tube | 24 |
Loose tube nominal diameter [mm] | 2.4 mm |
Outer jacket nominal thickness [mm] | 0.9 mm |
Cable outer diameter [mm] | 5.4 mm |
Cable version | n.a |
Standard put-up length on drum | 2100 m ± 5% |
CPR classification detail | B2ca-s1a,d0,a1 |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 32.0 kg/km / 21 lbs/1000ft |
Tensile performance - during installation | 1000 N (5 min.) |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1A |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Crush resistance - long term | 500 N/100mm (long term -15min) |
Crush resistance - long term test method | IEC 60794-1-21:E3A |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Impact resistance | 5 Nm, 3 impacts, d=20 mm, R=12,5 mm |
Impact resistance test method | IEC 60794-1-21:E4 |
Impact resistance acceptance criteria | no fiber breakage |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles, F= 20N |
Torsion test method | IEC 60794-1-21:E7 |
Torsion acceptance criteria | no fiber breakage |
Kink | d = 20 x cable diameter |
Kink acceptance criteria | no kink |
Cable bend | R=20 x cable diameter, 6 turns, 10 cycles, 23°C |
Cable bend - test method | IEC 60794-1-21:E11A |
Cable bend - acceptance criteria | no fiber breakage |
Repeated bending | R=10 x cable diameter, 25 cycles, m = 4Kg |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending acceptance criteria | no damage |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Temperature cycling | -20 °C +60 °C / -4 °F +140 °F |
Temperature cycling - reversible | -25 °C +60 °C / -13 °F +140 °F |
Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
Operation temperature | -20 °C to +60 °C / -4 °F to +140 °F |
Transport / store temperature | -25 °C to +60 °C / -13 °F to +140 °F |