Central loose tube cable, outdoor-use, FRP armour, HDPE sheath - black, 01x12-fibers G652.D

R855882

Fiber Reinforced Plastic (FRP) rod armoured central loose tube cable with excellent mechanical protection and thus secure rodent protected.

With up to 24 fibers maximum, suitable for outdoor duct or direct buried installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Central loose tube cable

Jacket material

UV stable HDPE

CPR classification Fca
Armour

Fiber reinforced plastic rod armoured (FRPA)

Fiber Count 12
Application

outdoor-use

Cable family code OX1PH
DIN/VDE Code A-DQ(ZN)B2Y (FRP 1,0)
DoP no.: D9915
Loose-tube count 1
Fiber count per tube 24
Loose tube nominal diameter [mm] 3 mm
Outer jacket nominal thickness [mm] 1.2 mm
Cable outer diameter [mm] 7.4 mm
Cable version

n.a

Standard put-up length on drum 2100/4100 m ± 5%
RoHS

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 52.0 kg/km / 35 lbs/1000ft
Tensile performance - in service

800 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

2500 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

1500 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

20 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling - reversible -25 °C +70 °C / -13 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Transport / store temperature -25 °C to +70 °C / -13 °F to +158 °F
Creating documents