Non-metallic central loose tube Micro-Cable for up to a maximum of 12 fibers, used outdoors for "air-blown" installations into Microducts
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | Central loose tube cable |
Jacket material | UV stable HDPE |
CPR classification | Fca |
Fiber type | G.657.A1 |
Fiber Count | 6 |
Application | outdoor-use |
Cable family code | MT1H |
DIN/VDE Code | A-D2Y |
DoP no.: | D9903 |
Loose-tube count | 1 |
Fiber count per tube | 12 |
Loose tube nominal diameter [mm] | 2 mm |
Outer jacket nominal thickness [mm] | 0.5 mm |
Cable outer diameter [mm] | 3 mm |
Cable version | Micro cable |
Standard put-up length on drum | 2100 m ± 5% |
RoHS | Pass |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 8.0 kg/km / 5 lbs/1000ft |
Tensile performance - during installation | 50 N (short term) |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Crush resistance - long term test method | IEC 60794-1-21:E3A |
Impact resistance | 1 Nm, 3 impacts, d=20 mm, R=300 mm |
Impact resistance test method | IEC 60794-1-21:E4 |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
Torsion test method | IEC 60794-1-21:E7 |
Torsion acceptance criteria | no damage |
Kink | d = 40 x cable diameter |
Kink test method | IEC 60794-1-21:E10 |
Kink acceptance criteria | no kink |
Cable bend | d=40 x cable diameter, 4 turns, 3 cycles |
Cable bend - test method | IEC 60794-1-21:E11A |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Repeated bending | R = 40 x cable diameter, 25 cycles |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending acceptance criteria | no damage |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Temperature cycling | -20 °C +70 °C / -4 °F +158 °F |
Temperature cycling - reversible | -30 °C +70 °C / -22 °F +158 °F |
Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
Operation temperature | -20 °C to +70 °C / -4 °F to +158 °F |
Transport / store temperature | -30 °C to +70 °C / -22 °F to +158 °F |