Central loose tube cable, outdoor-use, imp. rodent protection, LDPE sheath - black, 01x24-fibers G652.D

R855595

Non-metallic central loose tube cable with improved rodent protection. With up to 24 fibers maximum, suitable for outdoor duct installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Central loose tube cable

Jacket material

UV stable LDPE

CPR classification Fca
Armour

Intensified rodent protection

Fiber type

G.652.D

Fiber Count 24
Application

outdoor-use

Cable family code OX1GL
DIN/VDE Code A-DQ(BN)2Y wbg
DoP no.: D9908
Loose-tube count 1
Fiber count per tube 24
Loose tube nominal diameter [mm] 3.5 mm
Outer jacket nominal thickness [mm] 1.2 mm
Cable outer diameter [mm] 7.4 mm
RoHS

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 50.0 kg/km / 34 lbs/1000ft
Tensile performance - in service

800 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

2000 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

1000 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

EN 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling - reversible -25 °C +70 °C / -13 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Transport / store temperature -25 °C to +70 °C / -13 °F to +158 °F