Central loose tube cable, outdoor-use, SWA-steel wire armour, HDPE sheath - black, 01x24-fibers OM3

R855656

Steel wire armoured central loose tube cable with good mechanical protection and thus rodent protected.

The cable features a two jacket construction with up to 24 fibers maximum and is suitable for outdoor duct or direct buried installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Central loose tube cable

Jacket material

UV stable HDPE

CPR classification Fca
Armour

Steel wire armoured (SWA)

Cable design

Double jacket

Fiber type

OM3

Fiber Count 24
Application

outdoor-use

Cable family code OX1ELWH
DIN/VDE Code A-DQ(ZN)2YB2Y wbg (R 0,63vzk)
DoP no.: D9913
Loose-tube count 1
Fiber count per tube 24
Loose tube nominal diameter [mm] 3.1 mm
Outer jacket nominal thickness [mm] 1.3 mm
Cable outer diameter [mm] 9.9 mm
Cable version

n.a

Standard put-up length on drum 2100 m ± 5%
RoHS

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 150.0 kg/km / 101 lbs/1000ft
Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - during installation

4500 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

2000 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

20 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling - reversible -25 °C +70 °C / -13 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Transport / store temperature -25 °C to +70 °C / -13 °F to +158 °F