MiniCore cable, aerial-drop, universal-use, intensified, FRLSZH sheath - ivory, Fca, 04-fibers G657.A1

R857727

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

MiniCore cable

Jacket material

UV stable FRLSZH

CPR classification Fca
Fiber type

G.657.A1

Fiber Count 4
Application

universal-use

Cable family code UAF1000
DIN/VDE Code U-(ZN)H
DoP no.: D9011
Outer jacket nominal thickness [mm] 0.8 mm
Cable outer diameter [mm] 3.6 mm
Cable version

Aerial drop

Standard put-up length on drum 2100 m ± 5%

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 13.0 kg/km / 9 lbs/1000ft
Tensile performance - in service

1000 N (max. allow-able tension)

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,15 dB

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

500 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

3 Nm, 3 impacts, d=20 mm,R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L=2 m, rotation angle ±180°,5 cycles

Torsion test method

EN 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=15 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -20 °C +60 °C / -4 °F +140 °F
Temperature cycling - reversible -25 °C +60 °C / -13 °F +140 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -20 °C to +60 °C / -4 °F to +140 °F
Transport / store temperature -25 °C to +60 °C / -13 °F to +140 °F