DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | MiniCore cable |
Jacket material | UV stable FRLSZH |
CPR classification | Fca |
Fiber type | G.657.A1 |
Fiber Count | 4 |
Application | universal-use |
Cable family code | UAF250 |
DIN/VDE Code | U-(ZN)H |
DoP no.: | D9010 |
Outer jacket nominal thickness [mm] | 0.8 mm |
Cable outer diameter [mm] | 2.8 mm |
Cable version | Aerial drop |
Standard put-up length on drum | 2100 m ± 5% |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 9.0 kg/km / 6 lbs/1000ft |
Tensile performance - in service | 250 N (max. allow-able tension) |
Tensile performance - in service test method | IEC 60794-1-21:E1 |
Tensile performance - in service acceptance criteria | Δα ≤ 0,15 dB |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Crush resistance - long term | 500 N/100mm |
Crush resistance - long term test method | IEC 60794-1-21:E3A |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Impact resistance | 3 Nm, 3 impacts, d=20 mm,R=300 mm |
Impact resistance test method | IEC 60794-1-21:E4 |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L=2 m, rotation angle ±180°,5 cycles |
Torsion test method | IEC 60794-1-21:E7 |
Torsion acceptance criteria | no damage |
Cable bend | d=15 x cable diameter, 4 turns, 3 cycles |
Cable bend - test method | IEC 60794-1-21:E11A |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Repeated bending | R=20 x cable diameter, 25 cycles |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending acceptance criteria | no damage |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Temperature cycling | -20 °C +60 °C / -4 °F +140 °F |
Temperature cycling - reversible | -25 °C +60 °C / -13 °F +140 °F |
Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
Operation temperature | -20 °C to +60 °C / -4 °F to +140 °F |
Transport / store temperature | -25 °C to +60 °C / -13 °F to +140 °F |