DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | FiTH Cable |
Jacket material | FRLSZH |
CPR classification | Dca |
Minimum bending radius | 10 mm - no tension 10 mm - no tension |
Fiber type | G.657.A2 |
Fiber Count | 2 |
Application | indoor-use |
Cable family code | IFAF |
DIN/VDE Code | J-B(ZN)H |
DoP no.: | D9087 |
Loose-tube count | 1 |
Loose tube nominal diameter [mm] | 1.15 mm |
Cable outer diameter [mm] | 2.3 mm |
Cable version | Gel-free installation cable |
Standard put-up length on drum | 2’100 m ± 5% |
Warranty | R&Mfreenet |
Halogen free, acid gases | Pass |
RoHS | conform |
CPR classification detail | Dca-s1a,d0,a1 |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 5.5 kg/km / 4 lbs/1000ft |
Tensile performance - during installation | 200 N (5 min) |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB |
Crush resistance - long term | 400 N/ 100mm (15 min) |
Crush resistance - long term test method | IEC 60794-1-21:E3A |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Impact resistance | 3 Nm, 3 impacts, d=20 mm, R=12.5 mm |
Impact resistance test method | IEC 60794-1-21:E4 |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Kink | d= 4 x cable diameter |
Kink test method | IEC 60794-1-21:E10 |
Kink acceptance criteria | no kink |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Temperature cycling | -10 °C +60 °C / +14 °F +140 °F |
Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
Operation temperature | -10 °C to +60 °C / +14 °F to +140 °F |
Transport / store temperature | -10 °C to +60 °C / +14 °F to +140 °F |