Stranded loose tube cable, universal-use, CSTA-steel tape armour, FRLSZH sheath - green, Fca, 16x12-fibers G652.D

R857273

Corrugated steel tape armoured stranded loose tube cable with excellent mechanical protection and thus secure rodent protected.

The cable is built with up to 216 fibers in a 18-strand stranding and is suitable for indoor or outdoor duct or direct buried installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Stranded loose tube cable

Jacket material

UV stable FRLSZH

CPR classification Fca
Armour

Corrugated steel tape armoured (CSTA)

Fiber type

G.652.D

Fiber Count 192
Application

universal-use

Cable family code UT9x1,7ECF
DIN/VDE Code U-DQ(ZN)(SR)H wbg nx1,7
DoP no.: D9048
Loose-tube count 16
Fiber count per tube 12
Loose tube nominal diameter [mm] 1.7 mm
Loose-tube colour coding

1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black)

FRP/coat. CSM nominal thickness [mm] 1.7
Outer jacket nominal thickness [mm] 1.3 mm
Cable outer diameter [mm] 14 mm
Cable version

n.a

Standard put-up length on drum 2100 m ± 5%
Maximum length on drum 4100 m ± 5%
Halogen free, acid gases

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 210.0 kg/km / 141 lbs/1000ft
Tensile performance - in service

1100 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

3500 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

2500 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

20 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

EN 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -40 °C +70 °C / -40 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -40 °C to +70 °C / -40 °F to +158 °F
Transport / store temperature -40 °C to +70 °C / -40 °F to +158 °F
Creating documents