Stranded loose tube cable, universal-use, FRP armour, FRLSZH sheath - green, Fca, 12x12-fibers G657.A1

R857569

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Stranded loose tube cable

Jacket material

UV stable FRLSZH

CPR classification Fca
Armour

Fiber reinforced plastic rod armoured (FRPA)

Cable design

Double jacket

Fiber type

G.657.A1

Fiber Count 144
Application

universal-use

Cable family code UT3x2,3FPF
DIN/VDE Code U-DQH(ZN)BH (FRP...) nx2,3
DoP no.: D9070
Loose-tube count 12
Fiber count per tube 12
Loose tube nominal diameter [mm] 2.3 mm
Loose-tube colour coding

1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black)

FRP/coat. CSM nominal thickness [mm] 2.5 / 6.7
FRP rods (armour) nominal diameter (mm) 1.3
Outer jacket nominal thickness [mm] 1.3 mm
Cable outer diameter [mm] 19.4 mm
Cable version

n.a

Standard put-up length on drum 2100 m ± 5%
Halogen free, acid gases

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 390.0 kg/km / 262 lbs/1000ft
Tensile performance - in service

n.a.

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

10000 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

2000 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

25 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -40 °C +70 °C / -40 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -40 °C to +70 °C / -40 °F to +158 °F
Transport / store temperature -40 °C to +70 °C / -40 °F to +158 °F
Creating documents