Stranded loose tube cable, fire-resistant, universal-use, no armour, FRLSZH sheath - green, Fca, 05x12-fibers G657.A1

R857607

Non-metallic fire-resistant stranded loose tube cable with improved rodent protection.

The cable is built with up to 72 fibers in a 6-strand stranding and is suitable for indoor or outdoor duct installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Stranded loose tube cable

Jacket material

UV stable FRLSZH

CPR classification Fca
Armour

Intensified rodent protection

Fiber type

G.657.A1

Fiber Count 60
Application

universal-use

Cable family code QT6x2.3GF
DIN/VDE Code U-DQ(BN)H wbg nx2,3 fr
DoP no.: D9006
Loose-tube count 5
Fiber count per tube 12
Loose tube nominal diameter [mm] 2.3 mm
Loose-tube colour coding

1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black)

FRP/coat. CSM nominal thickness [mm] 2.8
Outer jacket nominal thickness [mm] 1.8 mm
Cable outer diameter [mm] 13 mm
Cable version

Fire-resistant

Standard put-up length on drum 2100 m ± 5%
Halogen free, acid gases

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 180.0 kg/km / 121 lbs/1000ft
Tensile performance - in service

1400 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

4500 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

1000 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=20 x cable diameter, 25 cycles

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

DESCRIPTION VALUE/VALUE RANGE
Temperature cycling -40 °C +70 °C / -40 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -40 °C to +70 °C / -40 °F to +158 °F
Transport / store temperature -40 °C to +70 °C / -40 °F to +158 °F
Creating documents