Fire resistant and steel wire armoured stranded loose tube cable with good mechanical protection and thus rodent protected.
The cable features a two jacket construction (both sheath in FRLSZH), is built with up to 72 fibers in a 6-strand stranding and is suitable for indoor or outdoor duct installation.
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | Stranded loose tube cable |
Jacket material | UV stable FRLSZH |
CPR classification | Fca |
Armour | Steel wire armoured (SWA) |
Cable design | Double jacket |
Fiber type | OM4 |
Fiber Count | 48 |
Application | universal-use |
Cable family code | QT6x2.3FWF |
DIN/VDE Code | U-DQHBH (R...vzk) nx2,3 fr |
DoP no.: | D9005 |
Loose-tube count | 4 |
Fiber count per tube | 12 |
Loose tube nominal diameter [mm] | 2.3 mm |
Loose-tube colour coding | 1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black) |
FRP/coat. CSM nominal thickness [mm] | 2.8 |
Outer jacket nominal thickness [mm] | 1.4 mm |
Cable outer diameter [mm] | 15.6 mm |
Cable version | Fire-resistant |
Standard put-up length on drum | 2100 m ± 5% |
Halogen free, acid gases | Pass |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 440.0 kg/km / 295 lbs/1000ft |
Tensile performance - in service | n.a. |
Tensile performance - in service test method | IEC 60794-1-21:E1 |
Tensile performance - in service acceptance criteria | Δα ≤ 0,05 dB |
Tensile performance - during installation | 5000 N |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Crush resistance - long term | 2000 N/100mm |
Crush resistance - long term test method | IEC 60794-1-21:E3A |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Impact resistance | 25 Nm, 3 impacts, d=20 mm, R=300 mm |
Impact resistance test method | IEC 60794-1-21:E4 |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
Torsion test method | IEC 60794-1-21:E7 |
Torsion acceptance criteria | no damage |
Cable bend | d=20 x cable diameter, 4 turns, 3 cycles |
Cable bend - test method | IEC 60794-1-21:E11A |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Repeated bending | R=20 x cable diameter, 25 cycles |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending acceptance criteria | no damage |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Temperature cycling | -40 °C +70 °C / -40 °F +158 °F |
Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
Operation temperature | -40 °C to +70 °C / -40 °F to +158 °F |
Transport / store temperature | -40 °C to +70 °C / -40 °F to +158 °F |