Stranded loose tube cable, universal-use, imp. rodent protection, FRLSZH sheath - green, Eca, 05x12-fibers G657.A1

R857030

Improved rodent-protected, non-metallic stranded loose tube cable with up to 72 fibers in a 6-strand stranding, for indoor or outdoor duct installation.

Technical Data

DESCRIPTION VALUE/VALUE RANGE
Cable type

Stranded loose tube cable

Jacket material

UV stable FRLSZH

CPR classification Eca
Armour

Intensified rodent protection

Fiber type

G.657.A1

Fiber Count 60
Application

universal-use

Cable family code UT6x2,3GF
DIN/VDE Code U-DQ(BN)H wbg nx2,3
DoP no.: D9057
Loose-tube count 5
Fiber count per tube 12
Loose tube nominal diameter [mm] 2.3 mm
Loose-tube colour coding

1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black)

FRP/coat. CSM nominal thickness [mm] 2.5
Outer jacket nominal thickness [mm] 1.4 mm
Cable outer diameter [mm] 11 mm
Cable version

n.a

Halogen free, acid gases

Pass

Mechanical Data

DESCRIPTION VALUE/VALUE RANGE
Cable weight 120.0 kg/km / 80 lbs/1000ft
Tensile performance - in service

1100 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

3500 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Cable bend - test method

IEC 60794-1-21:E11A

Creating documents