Improved rodent-protected, non-metallic stranded loose tube cable with up to 72 fibers in a 6-strand stranding, for indoor or outdoor duct installation.
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | Stranded loose tube cable |
Jacket material | UV stable FRLSZH |
CPR classification | Eca |
Armour | Intensified rodent protection |
Fiber type | OM4 |
Fiber Count | 60 |
Application | universal-use |
Cable family code | UT6x2,3GF |
DIN/VDE Code | U-DQ(BN)H wbg nx2,3 |
DoP no.: | D9057 |
Loose-tube count | 5 |
Fiber count per tube | 12 |
Loose tube nominal diameter [mm] | 2.3 mm |
Loose-tube colour coding | 1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black) |
FRP/coat. CSM nominal thickness [mm] | 2.5 |
Outer jacket nominal thickness [mm] | 1.4 mm |
Cable outer diameter [mm] | 11 mm |
Cable version | n.a |
Halogen free, acid gases | Pass |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 120.0 kg/km / 80 lbs/1000ft |
Tensile performance - in service | 1100 N |
Tensile performance - in service test method | IEC 60794-1-21:E1 |
Tensile performance - in service acceptance criteria | Δα ≤ 0,05 dB |
Tensile performance - during installation | 3500 N |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Cable bend - test method | IEC 60794-1-21:E11A |