Rodent-protected, non-metallic stranded loose tube cable with up to 72 fibers in a 6-strand stranding, for indoor or outdoor duct installation.
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable type | Stranded loose tube cable |
Jacket material | UV stable FRLSZH |
CPR classification | Eca |
Armour | Rodent protection |
Fiber type | G.652.D |
Fiber Count | 36 |
Application | universal-use |
Cable family code | UT6x1,7F |
DIN/VDE Code | U-DQ(ZN)H nx1,7 |
DoP no.: | D9020 |
Loose-tube count | 3 |
Fiber count per tube | 12 |
Loose tube nominal diameter [mm] | 1.7 mm |
Loose-tube colour coding | 1.red, 2.green - on each layer, rest of tubes white (fillers uncoloured or black) |
FRP/coat. CSM nominal thickness [mm] | 1.7 |
Outer jacket nominal thickness [mm] | 1.2 mm |
Cable outer diameter [mm] | 7.8 mm |
Cable version | n.a |
Standard put-up length on drum | 2100 m ± 5% |
Halogen free, acid gases | Pass |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Cable weight | 70.0 kg/km / 47 lbs/1000ft |
Tensile performance - in service | 800 N |
Tensile performance - in service test method | IEC 60794-1-21:E1 |
Tensile performance - in service acceptance criteria | Δα ≤ 0,05 dB |
Tensile performance - during installation | 2000 N |
Tensile Performance during Installation TestMethod | IEC 60794-1-21:E1 |
Tensile performance - during installation acceptance criteria | Δα ≤ 0,05 dB after test |
Crush resistance - long term | 1000 N/100mm |
Crush resistance - long term test method | IEC 60794-1-21:E3A |
Crush resistance - long term acceptance criteria | Δα ≤ 0,05 dB prior release, no damage |
Impact resistance | 10 Nm, 3 impacts, d=20 mm, R=300 mm |
Impact resistance test method | IEC 60794-1-21:E4 |
Impact resistance acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Torsion | L = 1 m, rotation angle ±180°, 10 cycles |
Torsion test method | IEC 60794-1-21:E7 |
Torsion acceptance criteria | no damage |
Cable bend | d=20 x cable diameter, 4 turns, 3 cycles |
Cable bend - test method | IEC 60794-1-21:E11A |
Cable bend - acceptance criteria | Δα ≤ 0,05 dB after test, no damage |
Repeated bending | R=20 x cable diameter, 25 cycles |
Repeated bending test method | IEC 60794-1-21:E6 |
Repeated bending acceptance criteria | no damage |
DESCRIPTION | VALUE/VALUE RANGE |
---|---|
Temperature cycling | -40 °C +70 °C / -40 °F +158 °F |
Installation temperature | -5 °C +50 °C / +23 °F +122 °F |
Operation temperature | -40 °C to +70 °C / -40 °F to +158 °F |
Transport / store temperature | -40 °C to +70 °C / -40 °F to +158 °F |