Gel-free central loose tube cable, universal-use, imp. rodent protected, FRLSZH sheath - turquoise, Cca, 01x12-fibers OM3

R870415

Technical Data

ОПИСАНИЕ ЦЕННОСТЬ / СТЕПЕНЬ ЦЕННОСТИ
Cable type

Central loose tube cable

Jacket material

UV stable FRLSZH

CPR classification Cca
Armour

Rodent protection

Minimum bending radius

no tension - 10 x cable diameter

no tension - 10 x cable diameter

Fiber type

OM3

Fiber Count 12
Application

universal-use

Cable family code UTd1GF FiRis
DIN/VDE Code U-BQ(BN)H wbg
DoP no.: D9088
Loose-tube count 1
Fiber count per tube 12
Loose tube nominal diameter [mm] 2.8 mm
Outer jacket nominal thickness [mm] 1.2 mm
Cable outer diameter [mm] 6.8 mm
Cable version

Gel-free installation cable

Standard put-up length on drum 2’100 m ± 5%
Warranty

R&Mfreenet

Halogen free, acid gases

Pass

RoHS

conform

CPR classification detail Cca-s1a,d0,a1

Mechanical Data

ОПИСАНИЕ ЦЕННОСТЬ / СТЕПЕНЬ ЦЕННОСТИ
Cable weight 32.0 kg/km / 21 lbs/1000ft
Tensile performance - in service

1000 N

Tensile performance - in service test method

IEC 60794-1-21:E1

Tensile performance - in service acceptance criteria

Δα ≤ 0,05 dB

Tensile performance - during installation

2000 N

Tensile Performance during Installation TestMethod

IEC 60794-1-21:E1

Tensile performance - during installation acceptance criteria

Δα ≤ 0,05 dB after test

Crush resistance - long term

2000 N/100mm

Crush resistance - long term test method

IEC 60794-1-21:E3A

Crush resistance - long term acceptance criteria

Δα ≤ 0,05 dB prior release, no damage

Impact resistance

10 Nm, 3 impacts, d=20 mm, R=300 mm

Impact resistance test method

IEC 60794-1-21:E4

Impact resistance acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Torsion

L = 1 m, rotation angle ±180°, 10 cycles

Torsion test method

IEC 60794-1-21:E7

Torsion acceptance criteria

no damage

Cable bend

d=20 x cable diameter, 4 turns, 3 cycles

Cable bend - test method

IEC 60794-1-21:E11A

Cable bend - acceptance criteria

Δα ≤ 0,05 dB after test, no damage

Repeated bending

R=10 x cable diameter, 25 cycles, m = 4Kg

Repeated bending test method

IEC 60794-1-21:E6

Repeated bending acceptance criteria

no damage

Climatic Data

ОПИСАНИЕ ЦЕННОСТЬ / СТЕПЕНЬ ЦЕННОСТИ
Temperature cycling -20 °C +70 °C / -4 °F +158 °F
Temperature cycling - reversible -25 °C +70 °C / -13 °F +158 °F
Installation temperature -5 °C +50 °C / +23 °F +122 °F
Operation temperature -20 °C to +70 °C / -4 °F to +158 °F
Transport / store temperature -25 °C to +70 °C / -13 °F to +158 °F